Volume 6, Issue 2 (12-2022)                   CRMS 2022, 6(2): 1-10 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Khalilpour A, Fallah S H, Gholamii Godarzi A, Amouei A, Asgharnia H A, Geraili Z. Study of the Intensity of Sound and Light in Faculties of Babol University of Medical Sciences. CRMS 2022; 6 (2) :1-10
URL: http://crms.mubabol.ac.ir/article-1-131-en.html
Environmental Health Department, Babol University of Medical Sciences, Babol, Iran. , Asieh.khalilpour@gmai.com
Abstract:   (2719 Views)
Background and Objective: Light and brightness are the first environmental factor for any type of activity. The other physical factor that has been considered in recent years is sound. Noise/sound and light can affect the quality of human performance. Therefore, the aim of this study was to evaluate the intensity of light and sound in the Faculties of Babol University of Medical Sciences.
Methods: Among 4 selected faculties, 25 classrooms and 25 offices were randomly chosen. The intensity of light was measured (both natural and artificial). The light level was measured using the S724997 device, whose metering sensor was mounted at a height of 24 in. (60 cm) from the floor. Sound was measured in classrooms during two periods of the presence and absence of students and university staff members. The sound level was measured using a sound level meter (SLM). Data were analyzed using SPSS 22.
Findings: The mean sound intensity of the classrooms at the time of the presence and absence of individuals was 59.10 dB, 59.09 dB, and 48.53 dB, respectively, which was higher than the standard. The mean light intensity was 445.44 and 535.93 lux in the classrooms and office, respectively, which was standard.
Conclusion: The results of this study indicated that the sound level was higher than the standard at all places. The light level was near-minimum standard in most places that should be improved. Therefore, because of the importance of these two issues, the necessary measures should be taken to remove the defects.
 
Keywords: Faculty, Light, Sound, Intensity
Full-Text [PDF 942 kb]   (1412 Downloads)    
Type of Study: Original Article | Subject: بهداشت حرفه ای
Received: 2022/12/17 | Accepted: 2022/12/31 | Published: 2023/01/28

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2026 CC BY-NC 4.0 | Current Research in Medical Sciences

Designed & Developed by : Yektaweb